GR-326-CORE Testing
| General Requirements for Singlemode Optical Connectors and Jumper Assemblies | |||
| Bellcore Test | Description | Recommended Test Equipment | |
| 4.4.2.1 | Thermal Age Test | 85°C for 168 hours |
• SE-Series • S-3800 • Walk In |
| 4.4.2.2 | Thermal Cycle Test | 168 hour cycle between -40°C and 70°C |
• SE-Series • S-3800 • Walk In |
| 4.4.2.3 | Humidity Aging Test | 75°C 95% for 168 hours |
• SE-Series • S-3800 • Walk In |
| 4.4.2.4 | Humidity/ Condensation Cycling Test | -10°C to 65°C 90-100% with fast heat-ups for condensation |
• SE-Series • S-3800 • Walk In |
| 4.4.2.5 | Dry-Out Step | 75°C for 24 hours |
• SE-Series • S-3800 • Walk In |
| 4.4.2.6 | Post-Condensation Thermal Cycle Test | 168 hour cycle between -40°C and 70°C |
• SE-Series • S-3800 • Walk In |
| 4.4.3.1 | Vibration Test | Vibration Sweep |
• Electrodynamic Vibration |
| 4.4.4.1 | Dust Test | Special Dust Test |
• Dust Chambers |
| 4.4.4.2 | Adhesive Test | 65°C for 7 days |
• SE-Series • S-3800 • Walk In |
Resources